Restricted packagePlease contact Micro Learn Online for access.

Training Package

Installation Standards Compliance Testing

🎬 Contains Videos

This package covers copper cabling segregation, PoE, tool selection and certification testing, helping learners make compliant installation decisions and interpret test results to diagnose faults.

For: Copper network installers and cabling technicians

£5.00 per learner

Restricted package

Installation Standards Compliance Testing is only available to approved organisations. Please contact Micro Learn Online for access.

Contact Micro Learn Online

About this package

Installation Standards, Compliance & Testing focuses on the standards and working practices that support reliable copper network installations. It connects decisions made during cable routing and termination with the measurements used to check a finished installation. Learners explore why a working connection or link light is not enough to demonstrate performance, and how formal testing provides evidence of installation quality before handover.

The first part explains cable segregation in accordance with BS EN 50174. It examines how nearby electrical cables can introduce electromagnetic interference, and how physical damage can affect data, telephone, security, alarm and AV services. The content also considers shared routes used by access control and building management systems. These topics help learners understand why separation, physical protection and coordination with other services matter on site.

The package then covers Remote Power and Power over Ethernet (PoE), including how copper cabling carries power alongside data. It explores compatibility across cables, connectors, patch panels, patch leads and powered devices, together with heat, voltage drop and safe operation under load. Tool selection follows, covering preparation of equipment lists, quantities and checks before work begins. Learners examine stripping, crimping, pulling and punch-down techniques, as well as the testing equipment used to investigate installation faults.

The final part explains copper certification, relevant national and international standards, and manufacturers’ best-practice guidance. It introduces performance measures such as wiremap, length and insertion loss, alongside fault diagnosis involving NEXT, or near-end crosstalk. Learners consider permanent-link and channel test models, interpret results and identify likely corrective actions. The emphasis is on understanding what tests establish, choosing appropriate equipment and using evidence to resolve faults rather than relying on visual inspection alone.

Who it’s for

This package suits copper network installers, structured cabling technicians and learners preparing for installation, termination or testing work. It is also relevant to those checking copper cabling quality and PoE compatibility before handover.

What’s covered

  1. Cable Segregation: Protecting Data and Other Services

    Explains segregation of data and electrical cabling in accordance with BS EN 50174, including how interference and physical damage affect copper communication services. Covers practical protection for data, telephone, security, alarm and AV cabling in shared service installations.

  2. Remote Power: PoE Standards and Safe Delivery

    Introduces how Remote Power and PoE deliver power alongside data over copper cabling. Examines whole-channel component compatibility, heating and voltage drop, safe handling of powered connections and stable operation under load.

  3. Copper Task Equipment: Tools, Quantities and Usage

    Covers selecting and quantifying tools for preparation, installation, termination and fault-finding, including checks on testing equipment. Explains stripping, crimping, pulling and punch-down techniques, and how poor workmanship can affect electrical performance.

  4. Copper Certification: Standards, Testing and Fault Finding

    Explains certification parameters, permanent-link and channel test models, and the role of standards and manufacturers’ guidance in determining acceptance criteria. Covers testing installed networks, interpreting results and diagnosing faults such as NEXT to identify likely causes and corrective actions.

Learning outcomes

By completing this package, learners can:

  • Describe the requirements for segregating data cables from electrical cables in accordance with BS EN 50174, including precautions to avoid interference or physical damage to data, telephone, security, alarm and AV systems.
  • Explain the requirements of Remote Power and Power over Ethernet (PoE) standards, including implications for cabling, device compatibility and safe system operation.
  • Select and use appropriate tools and testing equipment for copper cabling tasks, justifying each choice for installation, termination and fault-finding activities.
  • Explain the key test parameters used for copper cable certification in line with relevant industry standards, including how they confirm installation quality and performance.
  • Analyse how national and international standards, together with manufacturers’ best-practice guidance, influence compliant copper network installation and testing decisions.
  • Apply copper network testing procedures to installed systems to identify common faults such as NEXT, and interpret test results to determine likely causes and corrective actions.

What’s included

A deployable SCORM package with practical learning content, ready for your LMS.

How it works

Add access, upload the package to your LMS, and pay per learner who uses it.

Frequently asked questions

Does this package cover BS EN 50174 cable segregation?

Yes. It explains segregation of data cables from electrical cabling in accordance with BS EN 50174, along with precautions to protect data, telephone, security, alarm and AV services from interference and physical damage.

What does the package teach about Power over Ethernet?

It covers how PoE carries power and data over the same copper cabling, the need to match device and cabling capabilities, and safe operation. Topics include component compatibility across the channel, heat, voltage drop and checking powered devices under their operating load.

What is the difference between verification and copper certification testing?

Verification checks basic wiring and continuity, including opens, shorts and miswired pairs. Certification measures transmission performance against defined standards and limits; the package explains these measurements and how to interpret results when a link fails.

Does the content cover tool use as well as testing standards?

Yes. It covers tool selection and quantities, stripping, crimping, pulling and punch-down techniques, as well as fault-finding and copper testing equipment.

How is the package delivered, and does it include video?

The Micro Learn Online e-learning package is uploaded to your organisation’s own LMS for learners to access there. It includes video content.

Related training packages

Copper Network Fundamentals Infrastructure

This package covers copper signal transmission, electrical effects, structured cabling and component selection, helping learners understand installation faults and plan a basic copper network layout.

£5.00 per learner

Fibre Network Fundamentals Infrastructure

This package covers fibre transmission, structured cabling, network equipment and component selection, helping learners assess installation plans and choose infrastructure suited to performance and environmental requirements.

£5.00 per learner

Health Safety And Legal Compliance

This package covers health and safety law, risk assessment, asbestos, working at height, confined spaces and electrical safety, helping network cable installers recognise hazards and plan safer work.

£5.00 per learner

Fibre Installation Compliance Testing

This package covers fibre installation, standards, safety and testing, helping learners recognise causes of signal loss, select suitable equipment and interpret evidence of network compliance.

£5.00 per learner

Browse all Copper Network Fundamentals training