Restricted packagePlease contact Micro Learn Online for access.

Training Package

Standards Documentation And Technical Knowledge

🎬 Contains Videos

Learn to interpret network cabling documents, understand recognised standards and read basic decibel test results to support accurate installation decisions and identify excessive signal loss.

For: Trainee and early-career network cabling installers

£5.00 per learner

Restricted package

Standards Documentation And Technical Knowledge is only available to approved organisations. Please contact Micro Learn Online for access.

Contact Micro Learn Online

About this package

Standards, Documentation and Technical Knowledge develops the practical understanding needed to connect network cabling plans, installation requirements and test results. It focuses on three related areas: reading installation documents, working to recognised standards and understanding signal loss in decibels. Learners explore how these inform decisions about cable routes, port connections, equipment positions and whether a completed link meets its specified performance requirements.

The documentation content covers floor plans, patch lists, bills of materials and rack face layout plans. Learners examine drawing information, symbols and annotations, outlet positions, cable routes and termination points. Patch lists connect work-area outlets to patch panel ports and, where recorded, switch ports or services. Bills of materials support checks on component specifications and quantities, while rack layouts show equipment positions and available space in rack units. The course explains why incorrect connections, misread drawings and outdated information can undermine an otherwise tidy installation.

The standards content introduces British, international and industry standards at an awareness level, including the roles of BSI, ISO/IEC and TIA/EIA. It relates cable categories and performance requirements to installation practice, testing and interoperability. Specific coverage distinguishes the system performance requirements of BS EN 50173 from the installation practices addressed by BS EN 50174, then considers BS 6701 and its UK telecommunications scope. Learners also examine why design specifications, agreed routes, labelling and documentation need to be followed rather than changed informally on site.

The final part explains decibels as a logarithmic comparison of signal levels without relying on heavy mathematics. It covers attenuation, insertion loss and gain, then links signal loss to installation quality, including tight bends and poor terminations. Learners practise the basic reasoning involved in comparing measured loss with a stated test limit and recognising acceptable or excessive loss. This makes the package relevant to introductory installer training and to staff who need to understand how documentation, workmanship and testing fit together.

Who it’s for

This package suits trainee and early-career network cabling installers, including learners preparing for practical installation work. It also suits staff who need an introductory understanding of cabling documentation, standards and basic loss measurements.

What’s covered

  1. Reading floor plans and building layouts

    Introduces the main installation documents before focusing on floor plans, drawing information, symbols and annotations. Learners consider outlet positions, cable routes and the risks of working from the wrong or outdated drawing.

  2. Using patch lists and port connections

    Explains how patch lists record intended connections between work-area outlets, patch panel ports and, where specified, switch ports. It shows why correct port matching matters even when a cable passes its physical tests.

  3. Bills of materials and installation planning

    Covers the purpose of a bill of materials and the components it records, including cables, cabinets, panels, accessories and fixings. Learners explore checking quantities and specifications before work begins and distinguish procurement information from connection and layout records.

  4. Reading rack face layout plans

    Explains how rack diagrams show equipment placement, occupied space and remaining capacity. Learners interpret rack units and the planned positions of patch panels, switches, cable management and blanking panels.

  5. Why standards matter and who produces them

    Introduces cable categories as performance classifications and explains how standards support quality, safety and interoperability. It covers the roles of British, international and industry standards bodies and the references learners may encounter in project documents.

  6. Standards, installation testing and design specifications

    Explores how specified standards influence installation decisions, performance limits and testing expectations. Learners examine the importance of following the complete design specification, including routes, outlet schedules, containment, cable categories and termination requirements.

  7. BS EN 50173 and BS EN 50174

    Distinguishes the performance requirements of the finished cabling system from the practices used to install it. The content explains how component selection and workmanship both affect the ability to meet specified requirements.

  8. BS 6701: telecommunications equipment and cabling

    Introduces BS 6701 and its relationship with BS EN 50174 in UK telecommunications work. Coverage includes installation, operation, administration and maintenance, with attention to documentation, labelling and record keeping.

  9. Decibels, loss, gain and logarithmic thinking

    Explains a decibel as a ratio between signal levels and introduces the purpose of a logarithmic scale. Learners distinguish attenuation and insertion loss from gain and consider how cables, connectors and other passive components contribute to loss.

  10. How installation quality affects signal loss

    Connects workmanship with measured cabling performance. It examines how tight bends, pulling damage and poor terminations can contribute to signal loss, even when the cable itself is suitable.

  11. Reading test results and judging loss

    Explains how measured loss is compared with a stated loss budget or test limit. Learners develop a basic approach to interpreting pass/fail results and recognising when excessive loss may indicate installation problems.

Learning outcomes

By completing this package, learners can:

  • Identify the main types of industry documentation used in network cabling work, including floor plans, patch lists, bills of materials and rack face layout plans.
  • Explain how technical documentation supports installation planning, accuracy, consistency, maintenance and troubleshooting.
  • Interpret symbols, annotations, cable routes, termination points and rack layout information to support correct installation decisions.
  • Apply patch lists and floor plans to match physical ports, cable routes and equipment positions during a network cabling installation.
  • Describe the role of British, international and industry standards in promoting quality, safety, performance and interoperability in network cabling.
  • Assess the impact of not following standards or using outdated documentation on installation accuracy, compliance and system performance.
  • Interpret decibel readings in simple pass/fail terms to judge whether signal loss is acceptable or excessive in network cabling systems.

What’s included

A deployable SCORM package with practical learning content, ready for your LMS.

How it works

Add access, upload the package to your LMS, and pay per learner who uses it.

Frequently asked questions

Which network cabling documents does the package cover?

It covers floor plans, patch lists, bills of materials and rack face layout plans. Learners explore how to use them to identify cable routes, termination points, port connections, required materials and equipment positions.

Which cabling standards are included?

The package introduces British, international and industry standards, with specific coverage of BS EN 50173, BS EN 50174 and BS 6701. It explains their purposes and practical relevance at an awareness level rather than requiring learners to memorise standard numbers.

Do learners need advanced mathematics to understand the decibel content?

The decibel content is explained in practical terms without heavy mathematics. It introduces logarithmic thinking, loss and gain, then focuses on comparing measured loss with a stated test limit.

Does the package explain how workmanship affects test results?

Yes. It links installation faults, including tight bends and poor terminations, to signal loss and explains how basic loss results can help identify performance problems.

How is the package delivered?

The Micro Learn Online e-learning package is uploaded to your organisation’s own LMS for learners to access there. It is licensed per learner and includes video content.

Does this replace practical installation training?

The stated focus is knowledge and interpretation: reading documents, understanding standards and judging basic signal-loss results. It can support practical installer training, but the supplied content does not describe a hands-on installation assessment.

Related training packages

Copper Network Fundamentals Infrastructure

This package covers copper signal transmission, electrical effects, structured cabling and component selection, helping learners understand installation faults and plan a basic copper network layout.

£5.00 per learner

Fibre Network Fundamentals Infrastructure

This package covers fibre transmission, structured cabling, network equipment and component selection, helping learners assess installation plans and choose infrastructure suited to performance and environmental requirements.

£5.00 per learner

Health Safety And Legal Compliance

This package covers health and safety law, risk assessment, asbestos, working at height, confined spaces and electrical safety, helping network cable installers recognise hazards and plan safer work.

£5.00 per learner

Fibre Installation Compliance Testing

This package covers fibre installation, standards, safety and testing, helping learners recognise causes of signal loss, select suitable equipment and interpret evidence of network compliance.

£5.00 per learner

Browse all Core Knowledge training